Noise from the motor of an AquaClear usually means the impeller assembly needs cleaning. That is what Fluval’s manual says, and it gives step-by-step instructions for removing the motor and cleaning the impeller. This guide follows Fluval’s official AC Series manual.

Quick answer: Unplug the filter, empty the water from the filter case, remove the motor, and clean the impeller assembly until it is free of debris. If the noise continues, the impeller assembly may be worn and need replacing.
Safety first: Always unplug the filter before you put your hands in the water or take parts off. Don’t use soaps or detergents to clean it.
This is based on Fluval’s official manual for the AC Series (the AC110 edition), whose troubleshooting FAQ covers the AC20, AC30, AC50, AC70 and AC110. If you own an older AquaClear, check the manual that came with it.
How to clean the impeller and motor
The manual says the motor should be thoroughly cleaned every three months.

- Unplug the filter. Remove the filter cover and the filter basket, and discard the water that remains in the filter case.
- Remove the motor by gently twisting it a quarter turn in the direction of the arrow on the front. Ease the motor down slowly to prevent damage to the filter and the motor guide.
- Pull the impeller out of the impeller well and rinse it to remove the slime deposits that have built up.
- For more stubborn deposits, use a cotton swab or an impeller well brush. Then place the impeller back into position.
- Reinstall the motor.
- Restart and prime the filter. Fill the case completely with water, set the flow control lever to its lowest setting, plug in the cord and allow 30 to 45 seconds. Then adjust the flow and fit the cover.
Cleaning the rest of the filter
For routine cleaning, the manual says to rinse the collected debris from the case, the impeller cover and the impeller assembly in clear lukewarm water. The intake U-tube and extension tube can be cleaned with a filter stem brush to remove deposits. Don’t use soaps or detergents.
When the impeller needs replacing
The manual says the impeller assembly may need replacing. It is the filter’s only moving part and operates around the clock, so it eventually wears, and a worn impeller is not covered by the warranty. For the AC110, the manual’s spare parts list gives the impeller assembly as item A638. Check your own manual for your model’s part number.
Quick reference
| Symptom | What the manual suggests |
|---|---|
| Noise from the motor | Clean the impeller assembly; replace it if it is worn |
| Slower flow than normal | Clean or replace the media, rinse the intake sponge, and clean the impeller assembly. See our low flow guide |
| The filter won’t start | See our start and prime guide |
Frequently asked questions
Why is my AquaClear filter making noise?
The manual says noise from the motor suggests the impeller assembly needs cleaning. Unplug the filter, empty the water, remove the motor and clean all parts so the impeller assembly is free of debris.
How often should I clean the motor?
The manual says the motor should be thoroughly cleaned every three months.
Can I use soap to clean the impeller?
No. The manual says not to use soaps or detergents. Rinse the parts in clear lukewarm water.
Is a worn impeller covered by the warranty?
The manual says no. The impeller is the filter’s only moving part and operates around the clock, so it eventually wears and is not covered.
How do I remove the motor?
The manual says to twist it gently a quarter turn in the direction of the arrow on the front, then ease it down slowly to prevent damage to the filter and the motor guide.
Do I need to prime the filter after cleaning it?
Yes. The manual says to follow the operating instructions to restart and prime the filter after cleaning.
What this page doesn’t cover
This page covers the filter equipment only. It doesn’t give fish-health, medication or water-chemistry advice, and it doesn’t describe electrical repair.
Sources and last verified
- Fluval, AquaClear AC Series instruction manual (AC110 edition, official PDF): fluvalaquatics.com
Last verified: November 19, 2026, against the safety instructions, quick start guide, maintenance section and troubleshooting FAQ in that PDF.
